Author(s):
Shinde G. S., Jadhav R. S., Godge R. K, Kote R. B., Tambe V.B.
Email(s):
shinde.ganesh904@gmail.com
DOI:
10.52711/0974-360X.2024.00770
Address:
Shinde G. S.1, Jadhav R. S.1, Godge R. K 3, Kote R. B.1, Tambe V.B.2
1Department of Pharmaceutics, Institute of Pharmacy, Loni.
2Department of Pharmaceutical Chemistry, Institute of Pharmacy, Loni.
3Pravara Rural College of Pharmacy, Pravaranagar.
*Corresponding Author
Published In:
Volume - 17,
Issue - 10,
Year - 2024
ABSTRACT:
The Study aimed to develop a RP-HPLC method for simultaneous estimation of Lamivudine, Zidovudine and Nevirapine using UV detector in bulk and doage form. Methods: Inertsil BDS 3V C18 column (5µm, 150mm × 4.6mm) as stationary phase and 0.01M 1-octane Sulphonic acid: Methanol (50:50v/v, pH2.6) as mobile phase. The mobile phase was maintained at a flow rate of 1ml/min,run time 15 min and detection was carried out at 270 nm. Result: Lamivudine, Zidovudine and Nevirapine were found to be linear in the concentration range of 75-225µg/ml, 150-450µg/ml and 100-300µg/ml respectively. The result of % assay of marketed formulation was found as 101.93±0.1527, 100.86±0.2021and 94.2±0.1527 for Lamivudine, Zidovudine and Nevirapine respectively. Accuracy of the method was determined by performing recovery study and the result were found in the range of 100.9-101.4%, 100.1-100.7% and 99.0-99.9% for Lamivudine, Zidovudine and Nevirapine respectively. Percentage RSD of precision study of these drugs were found less than 2 percent which indicated good precision of the developed method. Conclusion: The proposed method was validated for linearity, accuracy, precision, and robustness. The proposed method is simple,rapid.precise and reproducible hence can be applied for routine quality control analysis of Lamivudine, Zidovudine and Nevirapine in pharmaceutical dosage form.
Cite this article:
Shinde G. S., Jadhav R. S., Godge R. K, Kote R. B., Tambe V.B.. RP-HPLC Method Development and Validation of Lamivudine, Zidovudine and Nevirapine in Bulk and Dosage form using UV Detector. Research Journal of Pharmacy and Technology. 2024; 17(10):5011-5. doi: 10.52711/0974-360X.2024.00770
Cite(Electronic):
Shinde G. S., Jadhav R. S., Godge R. K, Kote R. B., Tambe V.B.. RP-HPLC Method Development and Validation of Lamivudine, Zidovudine and Nevirapine in Bulk and Dosage form using UV Detector. Research Journal of Pharmacy and Technology. 2024; 17(10):5011-5. doi: 10.52711/0974-360X.2024.00770 Available on: https://www.rjptonline.org/AbstractView.aspx?PID=2024-17-10-55
REFERENCE:
1. Mahua, S., Ramesh, P., Sateesh, K. Development and validation of RP-HPLC and ultraviolet spectrophotometric methods of analysis for the quantitative estimation of antiretroviral drugs in pharmaceutical dosage forms. Journal of Chromatography. 2006; 830(2): 349–354. DOI: 10.1016/j.jchromb.2005.11.014
2. Jiang, X., Luo, A., Ren, H.. Lamivudine plus tenofovir combination therapy versus lamivudine monotherapy for HBV/HIV coinfection: a meta-analysis. Virology Journal. 2018; 15(139): 1-9. https://doi.org/10.1186/s12985-018-1050-3
3. Hudson, C.P. Zidovudine monotheraphy and prevention to mother to child HIV transmission. The Lancet Infectious Diseases. 2005; 2: 624-629. http:/doi.org/10.11016/S1473-3099(05)01259-4.
4. Hai, Yin Jiang., Hai, Jun Chen. Min, Na Zhang., Ying Yang., A.Min Deng , A ., Bing Ruan, A.. Nevirapine versus efavirenz for patients co-infected with HIV and tuberculosis: a systematic review and meta-analysis. International Journal of Infectious Diseases. 2014; 25: 130-135. https://doi.org/10.1016/j.ijid.2014.04.020.
5. Chandrabose, K., Vibhuti, K.Vivek., A.Piyush, T. Simultaneousquantitative determination of zidovudine and nevirapine in human Plasma Using Isocratic, Reverse Phase High Performance Liquid Chromatography, Tropical Journal of Pharmaceutical Science. 2009; 8(1): 79-86. DOI:10.4314/tjpr.v8i1.14715
6. Channabasavaraj, K., Prasada Rao, H,. Lakshmi, G. Development and validation of RP-HPLC method for the estimation of Nevirapine in bulk drug and tablets, Journal of Pharmaceutical Science and Research. 2009; 1(2): 78-82.
7. Estrela, C., Salvadori, C., Suarez-Kurtz, G.A rapid and sensitive method for simultaneous determination of lamivudine and zidovudine in human serum by on-line solid-phase extraction coupled to liquid chromatography/tandem mass spectrometry detection. Rapid Commun Mass Spectrom. 2004; 18(10): 1147-55. doi: 10.1002/rcm.1446.
8. Fan, B., Stewart, JT. Determination of zidovudine/ lamivudine/ nevirapine in human plasma using ion-pair HPLC. J Pharm Biomed Anal. 200; 28(5): 903-908. doi: 10.1016/s0731-7085(01)00708-7.
9. Sapna, R., Paresh P. Development and Validation of RP – HPLC Method for Estimation of Lamivudine and Dolutegravir Sodium in Synthetic Mixture. Research Journal of Pharmacy and Technology. 2020; 13(6): 2864-2868. DOI: 10.5958/0974-360X.2020.00510.7