ABSTRACT:
A reversed phase HPLC method is developed for the determination of citalopram in pharmaceutical dosage form. Chromatography was carried out on an inertsil C18 column using a mixture of methanol and phosphate buffer (pH 3.4) and acetonitrile (55:40:5 v/v/v) as the mobile phase at a flow rate of 1.35ml/min. Detection was carried out at 254nm. The retention time of the drug was 3.741min.The method produced linear responses in the concentration range of 10-50 µg/ml of Citalopram. The method was found to be applicable for the determination of the drug in tablets.


Cite this article:
Mousumi Karpillai, Sachin Dhangar. Development of RP-HPLC Method for Estimation of Citalopram Hbr. Research J. Pharm. and Tech. 4(12): Dec. 2011; Page 1807-1808.

Cite(Electronic):
Mousumi Karpillai, Sachin Dhangar. Development of RP-HPLC Method for Estimation of Citalopram Hbr. Research J. Pharm. and Tech. 4(12): Dec. 2011; Page 1807-1808.   Available on: https://www.rjptonline.org/AbstractView.aspx?PID=2011-4-12-23