ABSTRACT:
Objective: The aim of the study was to assess the location of the mental foramen from the apex of second premolar and the diameter of the mental foramen using cone beam computed tomography (CBCT) radiography. Methods: A total of 25 maxillofacial cone beam computed tomography scans were collected and evaluated for the distance of mental foramen from the apex of second premolar. The diameter of the mental foramen was also determined. Data were checked using Sirona software, statistically analyzed and results obtained. Results: The mean diameter of the mental foramen was 2.7mm-2.8mm. The mean distance from the apex of the second premolar to the upper border of the mental foramen was found to be 4.2mm-4.4mm. This was not statistically significant. Conclusion: Special concern should be directed to locate the mental foramen using CBCT/3D imaging to prevent injury to the mental nerve during Local anesthesia, periapical surgery, transalveolar extraction, Implant placement and invasive procedures.


Cite this article:
K. A. Jajashree, K. P. Senthilnathan, M. P. Santhosh Kumar. Assessment of Location and Dimensions of Mental Foramen– A CBCT Study.Research J. Pharm. and Tech 2018; 11(8):3486-3488. doi: 10.5958/0974-360X.2018.00644.3

Cite(Electronic):
K. A. Jajashree, K. P. Senthilnathan, M. P. Santhosh Kumar. Assessment of Location and Dimensions of Mental Foramen– A CBCT Study.Research J. Pharm. and Tech 2018; 11(8):3486-3488. doi: 10.5958/0974-360X.2018.00644.3   Available on: https://www.rjptonline.org/AbstractView.aspx?PID=2018-11-8-49


Recomonded Articles:

Research Journal of Pharmacy and Technology (RJPT) is an international, peer-reviewed, multidisciplinary journal.... Read more >>>

RNI: CHHENG00387/33/1/2008-TC                     
DOI: 10.5958/0974-360X 

1.3
2021CiteScore
 
56th percentile
Powered by  Scopus


SCImago Journal & Country Rank

Journal Policies & Information


Recent Articles




Tags


Not Available