Author(s): Dmytro Gushcha, Vitalii Parii, Dmytro Tyshko, Andrii Mykhailov, Dina Shpak

Email(s): dantistom@ukr.net

DOI: 10.5958/0974-360X.2019.00703.0   

Address: Dmytro Gushcha1*, Vitalii Parii2, Dmytro Tyshko3, Andrii Mykhailov4, Dina Shpak4
1Bogomolets National Medical University, Candidate of Medical Sciences, Associate Professor, Kiev, Ukraine.
2Bogomolets National Medical University, Candidate of Medical Sciences, Assistant, Kiev, Ukraine.
3Bogomolets National Medical University, Candidate of Medical Sciences, Associate Professor, Kiev, Ukraine.
4Bogomolets National Medical University, Candidate of Medical Sciences, Chief of the Orthodontic Department, Kiev, Ukraine.
*Corresponding Author

Published In:   Volume - 12,      Issue - 9,     Year - 2019


ABSTRACT:
The purpose of this study was to find out the electrical-chemical behavior of Ni-Cr, Co-Cr alloys and ceramics using the ZrO2-HFO2-Y2O3 system in vitro. The study was conducted using the System NH (Germany) and Starbond CoS (Germany) prefabricated alloys, previous processing-free; and the Nacera Pearl (Germany) ceramics using the ZrO2-HFO2-Y2O3 system, represented with frames manufactured in a dental technical laboratory, without subsequent veneering. There were two identical samples, each of them put in the electrical-chemical cell with 3% NaCl water solution, its temperature equal to 37°?. The potentials were evaluated using the potentiostat which defined the data of both samples in the cell. The experiment lasted for 5 days. The obtained results were recorded each hour throughout the working day. The parameters (values, positive or negative charge) of electrical-chemical potential on both identical samples from the System NH alloy have been changing intermittently. We have concluded that under certain conditions there may appear electrical current between the samples obtained from the same alloy, located in the same medium, unaffected by any external factors (heat, mechanical influence, etc.). The up-to-date methods of measuring the potentials and currents between the metallic dental prostheses may reflect the electrical balance by the photo, at the certain moment, so they are characterized by sufficiently high margin of error to be used while deciding on the certain alloy.


Cite this article:
Dmytro Gushcha, Vitalii Parii, Dmytro Tyshko, Andrii Mykhailov, Dina Shpak. The Study of Ni-Cr, Co-Cr Dental Alloys and Ceramics Chemical Indifference using ZrO2-HfO2-Y2O3 System in Vitro. Research J. Pharm. and Tech 2019; 12(9):4085-4089. doi: 10.5958/0974-360X.2019.00703.0

Cite(Electronic):
Dmytro Gushcha, Vitalii Parii, Dmytro Tyshko, Andrii Mykhailov, Dina Shpak. The Study of Ni-Cr, Co-Cr Dental Alloys and Ceramics Chemical Indifference using ZrO2-HfO2-Y2O3 System in Vitro. Research J. Pharm. and Tech 2019; 12(9):4085-4089. doi: 10.5958/0974-360X.2019.00703.0   Available on: https://www.rjptonline.org/AbstractView.aspx?PID=2019-12-9-3


Recomonded Articles:

Research Journal of Pharmacy and Technology (RJPT) is an international, peer-reviewed, multidisciplinary journal.... Read more >>>

RNI: CHHENG00387/33/1/2008-TC                     
DOI: 10.5958/0974-360X 

1.3
2021CiteScore
 
56th percentile
Powered by  Scopus


SCImago Journal & Country Rank

Journal Policies & Information


Recent Articles




Tags


Not Available