Author(s): Myat San Yi, Khin Than Yee, Mi Mi Khaing, Soe Lwin, Tin Moe Nwe, Farah Naz, Amnor Aidiliana bt Amir, Ei Mon Mon Kyaw

Email(s): myatsanyee@gmail.com

DOI: 10.52711/0974-360X.2026.00581   

Address: Myat San Yi1, Khin Than Yee2, Mi Mi Khaing3, Soe Lwin2, Tin Moe Nwe2, Farah Naz1, Amnor Aidiliana bt Amir1, Ei Mon Mon Kyaw4
1Suri Seri Begawan Hospital, Kuala Belait, Brunei Darussalem.
2Universiti Kuala Lumpur (Royal College of Medicine Perak), Ipoh, Malaysia.
3Segi University, Sibu, Malaysia.
4Luton and Dunstable Hospital, United Kingdom.
*Corresponding Author

Published In:   Volume - 19,      Issue - 9,     Year - 2026


ABSTRACT:
Intrauterine device is a widely used reversible method of contraception, preferred worldwide due to long duration of birth control effect and ease of use. 50- Year- old lady presented to Emergency with epigastric pain for one day with vomiting. After necessary investigations, found out one misplaced IUD inside the peritoneal cavity and another one was inside the uterus. Laparoscopic removal was successfully done and she was discharged completely safe and sound. This case-based evidence confirmed the effective approach of minimally invasive surgery for the removal of misplaced IUD. Clinicians should be aware of possible complications of misplaced IUD and once recognized, prompt removal with collaborative and competent surgical skills is the key for the successful management.


Cite this article:
Myat San Yi, Khin Than Yee, Mi Mi Khaing, Soe Lwin, Tin Moe Nwe, Farah Naz, Amnor Aidiliana bt Amir, Ei Mon Mon Kyaw. A Needle in the Hay stack: Misplaced IUCD. Research Journal Pharmacy and Technology. 2026;19(9):4151-5. doi: 10.52711/0974-360X.2026.00581

Cite(Electronic):
Myat San Yi, Khin Than Yee, Mi Mi Khaing, Soe Lwin, Tin Moe Nwe, Farah Naz, Amnor Aidiliana bt Amir, Ei Mon Mon Kyaw. A Needle in the Hay stack: Misplaced IUCD. Research Journal Pharmacy and Technology. 2026;19(9):4151-5. doi: 10.52711/0974-360X.2026.00581   Available on: https://www.rjptonline.org/AbstractView.aspx?PID=2026-19-9-27


REFERENCES:
1.    World Health Organization, Intrauterine Devices (IUDs). https://www.who.int/news-room/fact-sheets/detail/intrauterine-devices Geneva: World Health Organization;2023
2.    Günday ÖK. Successful Laparoscopic Treatment of Intrauterine Device and Complication Causing Uterine Rupture. World J Surg Surgical Res. 2018; 1: 1068
3.    Neha Varun, Abhinav Jain, Aruna Nigam, Sana Noor, Nidhi Gupta, Sumedha Sharma. Approach Towards Misplaced or Malposition IUCD: Lessons Learned Journal of Clinical and Diagnostic Research. 2019 May; 13(5): QC01-QC04 DOI: 10.7860/JCDR/2019/40534.12835
4.    Marchi NM, Castro S, Hidalgo MM, Hidalgo C, Monteiro-Dantas C, Villarroeal M, et al. Management of missing strings in users of intrauterine contraceptives. Contraception. 2012; 86(4): 354–358. 
5.    Barsaul M, Sharma N, Sangwan K. 324 cases of misplaced IUCD--a 5-year study. Trop Doct. 2003; 33(1): 11–12. 
6.    Andersson K, Ryde-Blomqvist E, Lindell K, Odlind V, Milsom I. Perforations with intrauterine devices. Report from a Swedish survey. Contraception. 1998; 57: 251–255
7.    Zakin D, Stern WZ, Rosenblatt R. Complete and partial uterine perforation and embedding following insertion of intrauterine devices. Obstet Gynecol Surv. 1981; 36(7): 335–53. doi: 10.1097/00006254-198107000-00001.  
8.    Sankareswari R, Indira, Geetha K, Vani S. Misplaced and Migrated IUCD: A case report. J Evol Med Dent Sci. 2014; 3(25): 7031-5.
9.    Rao RP. Lost intrauterine devices and their localization. J Reprod Med. 1978; 20: 195–9.
10.    Krupa BM, Manjula, Swarup A. Case report: misplaced copper-T device. Int J Sci Res. 2015; 4(6): 2229-30.
11.    Wildemeersch D, Hasskamp T, Goldstuck N (2016) Side effects of intrauterine devices are often related to disproportion with the endometrial cavity-is there a role for pre- insertion ultrasound? Eur J Obstet Gynecol Reprod Biol 201: 215-217
12.    Sinha M, Gupta R, Tiwari A. Minimally invasive surgical approach to retrieve migrated intrauterine contraceptive device. Int J Reprod Contracept Obstet Gynecol. 2013; 2:147-51.
13.    Wildemeersch D, Thomas Hasskamp ,and Norman D Goldstuck: Malposition and displacement of intrauterine devices– diagnosis, management and prevention. Clinical Obstetrics, Gynecology and Reproductive Medicine. 2(3): 183-188 doi: 10.15761/COGRM.1000145
14.    Wildemeersch D, Hasskamp T, Goldstuck N.  Intrauterine devices that do not fit well cause side effects, become embedded, or are expelled and can even perforate the uterine wall. J Minim Invasive Gynecol. 2015; 22: 309-310.
15.    Goldstuck N, Wildemeersch D. Role of uterine forces in intrauterine device embedment, perforation, and expulsion. Int J Womens Health. 2014; 6: 735-744. 
16.    Cornelis De Kroon https://doi.org/10.1093/HUMREP/DEG433
17.    Nigam A, Biswas R, Mishra A. The value of transvaginal ultrasound to monitor the position of an intrauterine device after insertion. A technology assessment study. Misplaced intrauterine contraceptive device: an enigma. Open Access J Contracept. 2011; 2: 1-3.
18.    Sun X, Xue M, Deng X, Lin Y, Tan Y, Wei X. Clinical characteristic and intraoperative findings of uterine perforation patients in using of intrauterine devices (IUDs). Gynecol Surg. 2018; 15(1): 3
19.    Dahiya K, Duhan N, Nanda S, Lakra P. Misplaced Intrauterine device: Endoscopic management. South Asian Federation Obstet Gynaecol. 2010; 2(2): 137-9.
20.    Ingec M, Kumtepe Y, Kadanali S, Ozdiller O. A rare case of ileal embedding by an intrauterine device. Eur J Contracept Reprod Health Care 2005; 10: 29–31
21.    Inal MM, Ertopçu K, Ozelmas I. The evaluation of 318 intrauterine pregnancy cases with an intrauterine device. Eur J Contracept Reprod Health Care. 2005; 10(4): 266-271
22.    Nitke S, Rabinerson D, Dekel A, Sheiner E, Kaplan B, Hackmon R. Lost levonorgestrel IUD: Diagnosis and Therapy. 2004; 69(4): 289-293                    
23.    World Health Organization (WHO); Mechanism of action, safety and efficacy of intrauterine devices, WHO Technical Report. WHO Geneva; Switzerland, 1987;753.
24.    Adoni, A. ∙ Ben Chetrit, A.   The management of intrauterine devices following uterine perforation. Contraception. 1991; 57: 251-255
25.    Gupta M, Jain G. Misplaced IUCD: Challenges and Management. People’s Journal of Scientific Research. 2016; 9(2); 12-15
26.    Fakih MN, Al-Wahab ZR. Laparoscopic Management of an Intrauterine Device Perforating the Uterus and Adherent to the Rectum and Ovary: A Case Report - PMC Cureus.2026 Jan 16; 18(1) : e101683



Recomonded Articles:

Research Journal of Pharmacy and Technology (RJPT) is an international, peer-reviewed, multidisciplinary journal.... Read more >>>

RNI: CHHENG00387/33/1/2008-TC                     
DOI: 10.52711/0974-360X 

1.3
2021CiteScore
 
56th percentile
Powered by  Scopus


SCImago Journal & Country Rank

Journal Policies & Information


Recent Articles




Tags


Not Available